Portable digital multimeters
FLK-27-2
Description: Digital multimeter; LCD; (6000); Bargraph: 33segm.40x/s; IP67
Category: Portable digital multimeters
Manufacturer part number: FLK-27-2
Element14
Mouser
Manufacturer | FLUKE |
---|---|
Type of meter | digital multimeter |
Measurement | AC current |
Measurement | AC voltage |
Measurement | capacitance |
Measurement | DC current |
Measurement | DC voltage |
Measurement | duty cycle |
Measurement | frequency |
Measurement | relative |
Measurement | resistance |
Measurement | temperature |
Kind of display used | LCD |
Display parameters | (6000) |
Bargraph | 33 segm. 40x/s |
DC voltage measuring range | 0.1...600mV |
DC voltage measuring range | 6V |
DC voltage measuring range | 60V |
DC voltage measuring range | 600V |
DC voltage measuring range | 1kV |
DC voltage measuring accuracy | ±(0.05% + 1 digit) |
AC voltage measuring range | 0.1...600mV |
AC voltage measuring range | 6V |
AC voltage measuring range | 60V |
AC voltage measuring range | 600V |
AC voltage measuring range | 1kV |
AC voltage measuring accuracy | ±(2% + 3 digit) |
DC current measuring range | 0.1...600µA |
DC current measuring range | 6mA |
DC current measuring range | 60mA |
DC current measuring range | 400mA |
DC current measuring range | 6A |
DC current measuring range | 10A |
DC current measuring accuracy | ±(0.2% + 2 digit) |
AC current measuring range | 0.1...600µA |
AC current measuring range | 6mA |
AC current measuring range | 60mA |
AC current measuring range | 400mA |
AC current measuring range | 6A |
AC current measuring range | 10A |
AC current measuring accuracy | ±(1.5% + 2 digit) |
Resistance measuring range | 100mΩ...600Ω |
Resistance measuring range | 6kΩ |
Resistance measuring range | 60kΩ |
Resistance measuring range | 600kΩ |
Resistance measuring range | 6MΩ |
Resistance measuring range | 50MΩ |
Capacitance measuring range | 10pF...10nF |
Capacitance measuring range | 100nF |
Capacitance measuring range | 1µF |
Capacitance measuring range | 10µF |
Capacitance measuring range | 100µF |
Capacitance measuring range | 9.999mF |
Capacitance measuring accuracy | ±(1%+ 2 digit) |
Frequency measuring range | 10mHz...199.99Hz |
Frequency measuring range | 1999.9Hz |
Frequency measuring range | 19.999kHz |
Frequency measuring range | 199.99kHz |
Frequency measuring accuracy | ±(0.005%+1 digit) |
Temperature measuring range | -200...1090°C |
Temperature measurement accuracy | ±(1% + 10 digit) |
Conductance measuring accuracy | ±(1% + 10digit) |
Resistance measuring accuracy | ±(0.2%+1 digit) |
Temperature measurement resolution | 0.1°C |
Conductance measurement | 0.01...60nS |
Duty cycle factor | 0...99.9% |
Duty cycle factor measurement accuracy | 0,2% per kHz + 0,1% |
Diode test | 1mA @2.8V |
Continuity test | acoustic indication |
IP rating | IP67 |
Weight with battery | 517g |
Power supply | battery LR6 AA 1,5V x3 |
Standard equipment | test leads |
Conform to the norm | CAT III 1000V |
Conform to the norm | CAT IV 600V |
Conform to the norm | EN 61010 |
Related items | FLK-80BK-A |
Related items | FLK-80PJ-1 |
Related items | FLK-80PJ-9 |
Related items | FLK-80PJ-EXT |
Related items | FLK-80PK-1 |
Related items | FLK-80PK-3A |
Related items | FLK-80PK-8 |
Related items | FLK-80PK-9 |
Related items | FLK-80PK-11 |
Related items | FLK-80PK-22 |
Related items | FLK-80PK-24 |
Related items | FLK-80PK-25 |
Related items | FLK-80PK-26 |
Related items | FLK-80PK-27 |
Related items | FLK-80PR-60 |
Related items | FLK-80PT-EXT |
Related items | FLK-80T-150UA |
Dimensions (W x H x D) | 100x198x63.5mm |
Measuring instrument features | auto and manual ranging |
Measuring instrument features | automatic power-off |
Measuring instrument features | backlit keypad |
Measuring instrument features | HOLD function |
Measuring instrument features | MIN/MAX/MEAN/REL function |
Measuring instrument features | shock-resistant case |
Battery/ rechargeable battery | battery LR6 AA 1,5V x3 |
Illumination | yes |